Spectrum Analyzers : Atten Electronics AT6005

AT6000 series spectrum analyzer have exceed 500MHZ frequency (0.15 ~1050MHZ) 50MHZ step frequency and fine adjust to the center frequency, compose the convenient frequency-domain test.AT6011 have the tracking signal generator


Frequency range:0.15~500MHz


Stability: ±10ppm / year


Aging: ± 2ppm each year


Resolution of frequency display:10kHz(5 digit)


Readout accuracy: ±2%* sweepwidth+5*10-3* CF+10kHz


CF adjustment range:0 .15~500MHz


Frequency synthesize:TCXO,DDS


Sweep width range: zero steps and 1-500MHz (1-2-5 steps)


Sweep Width accuracy: ±10%


Resolution Bandwidth:400kHz ±20kHz


Video-Filter Bandwidth:4kHz


Sweep time:20ms


Amplitude Specifications 0.15~500MHz


Range: -100dBm~+13dBm


Display: CRT,8*10div


Display calibration:10dB/div,logarithmic


Display range:80dB(10 dB/div)


Amplitude Frequency Response


10 dB Attenuation,Zero Step,Resolution Bandwidth


400kHz,Signal -17 dBm:<±4 dB


LCD Display:2*16,Center frequency,Sweep frequency width,Reference Level


Accuracy(Input attenuation):=±2dB/10dB


Reference level range:-27 dBm~+13 dBm(each 10dB)


Accuracy:(Reference level)250MHz(CF),Zero step,RBW400kHz:±2 dB


Average noise level:=-90 dBm(RBW20kHz VBW4kHz)


Third order intermod.:at -27dBm two signal >3MHz apart:=-60 dBc


2nd harmonic suppression:-27 dBm,0 dB attenuation,=-50 dBc


VSWR (Attenuation=10 dB):typ. 1.5:

Improve your cash flow by requesting a lease quote on a Atten Electronics AT6005. Calibration available for an additional charge. We carry over 300 test equipment manufacturers.

  • Model: AT6005
  • Manufactured by: Atten Electronics
  • Base Frequency: 150 KHz
  • Max Frequency: 500 MHz

Portable Body Massager



Detailed Product Description

1)The Ideal "Take-Anywhere" Massager
2)Lightweight and compact for the home, office or gym.
3)It's a portable massager, you can enjoy it for relaxation everywhere , and good

for your Shoulders, Waist, Back of the Body, Thigh and Crus. etc.
4)With it, you can get back from the fatigue and stimulate , the blood circulation,

relieve the muscular fatigue & pain.

Inner packing:
1pc/gift box with polybag
Box dimensions: 11.5x11.5x12.2cm

Outer packing:
Corrugated box
36pcs/ctn
Carton dimensions: 47.5x36x38.6cm
N.W.: 9.0kg
G.W.: 10.0kg

Conveyance:
Qty/20' FCL: 14,148 pcs
Qty/40' FCL: 29,448pcs
Qty/40' HQ: 37,080pcs


Skin Analyzer



Detailed Product Description

Features:

1) Facial moisture and oil detector

2) 12/24 hour system clock

3) Alarm function

4) Displays facial water level

5) Displays facial oil level

6) Displays facial age: rough/soft



Inner packing:

Potted molded case



Outer packing:

100pcs/ctn

Carton dimensions: 74.0 x 23.0 x 42.5cm

N.W.: 13kg

G.W.: 14kg



Conveyance:

Qty/20' FCL: 33,100 - 35,900pcs

Qty/40' FCL: 74,600pcs

Qty/40' HQ: 94,000pcs





Photon Portable gas analyzer using IR sensors.

Photon is a flue gas analyzer using infrared sensors as the main measuring method. The flue gas analyzer can also be fitted with up to 6 electrochemical sensors for other gases. The modular construction of this infrared analyzer allows it to be configured to suit virtually all wishes from the user.
The sensor ranges can also be chosen to exactly suit the measuring operations required. In addition, the infrared analyzer is fitted with a range of analog inputs and outputs, to guarantee that measuring data can be transferred and documented with ease.
The analyzer can thus also be used for a range of control functions.


Standard configuration

  • Measurement of gas concentrations
    • The following gases can be measured using NDIR technology: CO, CO2, CH4, NO, NO2, N2O , SO2
    • Please call for information on other gases
    • O2 concentration is measured using an electrochemical sensor.
    • O2 concentration: measured using an partial press. Sensor - option.
    • The following toxic gases can be measured using electrochemical sensors: H2, H2S. Please call for information about other gases.
  • Measurement of further parameters:
    • flue gas and ambient temperature measurement
    • Pressure, draft, and differential pressure measurement with a resolution of 0.1 Pa.
    • Ambient pressure measurement with a resolution of 0.1hPa.
    • 8 Temperature channels (4 thermocouples and 4 thermistors) - option
  • Calculations
    • CO2 concentration if no CO2 sensor is fitted.
    • Calculation of all relevant combustion parameters.
    • Calculation of absolute and relative mass concentrations for the measured gases.
    • Calculation of absolute and relative volumetric concentrations for all measured gases.
  • Preparation and display of measured values:
    • All measured and calculated values can be displayed as averaged values as well. Averaging time can be chosen from the series: 2, 10, 20, 30, 60, 120, and 180 seconds.
    • Single and triple long-term measurements (XL measurements). Period for long-term measurements chosen from the series: 10 s, 20 s, 30 s, 1 min., 5 min., 10 min., 15 min., 20 min., 30 min.
    • Single or continuous storage of results. One set of data will contain all measured and calculated values.
    • Memory MMC 256MB (1M sets of data).
    • Complete software package for the PC to process readings and communicate on-line.
  • Software features
    • Automatic zero calibration on switch-on
    • All parameters can be freely programmed
    • Complete list of 10 standard fuels
    • Freely programmable fuels
    • Continuous automatic monitoring of instrument function with acoustic warning and detailed information under "Control List"
    • Cross-sensitivity and temperature drift of gas sensors is fully compensated
    • Temperature and ambient pressure compensation for IR sensors
  • Hardware features
    • Flash memory for all instrument settings
    • Flash programme memory allows simple programme update from computer
    • Integral clock/calendar with separate buffer battery
    • Mains supply 110/230 VAC, 50-60Hz
    • Large LCD display (320 x 240) with backlighting
    • Internal dot matrix printer 57 mm wide
    • Mechanical keys covered with a dust and water resistant foil
    • Solenoid valve for automatic zeroing of the sensors
    • PC interface RS232C for communication with the analyzer and data transfer